SBR01-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, Opaque, enterprises, Counter32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC; cityron MODULE-IDENTITY LAST-UPDATED "201707240000Z" ORGANIZATION "CITYRON" CONTACT-INFO ".." DESCRIPTION "Some stuff MIB definitions." REVISION "201707240000Z" DESCRIPTION "Some stuff MIB definitions." ::= { enterprises 47777 } products OBJECT IDENTIFIER ::= { cityron 1 } sbr01 OBJECT IDENTIFIER ::= { products 1 } system OBJECT IDENTIFIER ::= { sbr01 1 } conditioners OBJECT IDENTIFIER ::= { sbr01 2 } conditioner1 OBJECT IDENTIFIER ::= { conditioners 1 } conditioner2 OBJECT IDENTIFIER ::= { conditioners 2 } conditioner3 OBJECT IDENTIFIER ::= { conditioners 3 } conditioner4 OBJECT IDENTIFIER ::= { conditioners 4 } conditioner5 OBJECT IDENTIFIER ::= { conditioners 5 } conditioner6 OBJECT IDENTIFIER ::= { conditioners 6 } conditioner7 OBJECT IDENTIFIER ::= { conditioners 7 } conditioner8 OBJECT IDENTIFIER ::= { conditioners 8 } error OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { system 1 } tempRoom OBJECT-TYPE SYNTAX Integer32 ( 0 .. 7 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Room temperature" ::= { system 2 } setTemp OBJECT-TYPE SYNTAX Integer32 (160..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature of activation of additional air conditionerss" ::= { system 3 } alarmTemp OBJECT-TYPE SYNTAX Integer32 (160..400) MAX-ACCESS read-write STATUS current DESCRIPTION "Emergency temperature" ::= { system 4 } minCondCnt OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of air conditioners in operation" ::= { system 5 } rotTime OBJECT-TYPE SYNTAX Integer32 (4..24) MAX-ACCESS read-write STATUS current DESCRIPTION "Rotation time, in hours" ::= { system 6 } timeError OBJECT-TYPE SYNTAX Integer32 (3..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Error response time, in minutes" ::= { system 7 } localTimeSec OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The operating time of the controller, in seconds" ::= { system 8 } -------------------------------------------------------- addr1 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 1" ::= { conditioner1 1 } addr2 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 2" ::= { conditioner2 1 } addr3 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 3" ::= { conditioner3 1 } addr4 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 4" ::= { conditioner4 1 } addr5 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 5" ::= { conditioner5 1 } addr6 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 6" ::= { conditioner6 1 } addr7 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 7" ::= { conditioner7 1 } addr8 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Air Conditioner Number 8" ::= { conditioner8 1 } -------------------------------------------------------- errorC1 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner1 2 } errorC2 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner2 2 } errorC3 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner3 2 } errorC4 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner4 2 } errorC5 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner5 2 } errorC6 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner6 2 } errorC7 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner7 2 } errorC8 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Error" ::= { conditioner8 2 } -------------------------------------------------------- tempInC1 OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner1 3 } tempInC2 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner2 3 } tempInC3 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner3 3 } tempInC4 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner4 3 } tempInC5 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner5 3 } tempInC6 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner6 3 } tempInC7 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner7 3 } tempInC8 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner IN" ::= { conditioner8 3 } -------------------------------------------------------- tempOutC1 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner1 4 } tempOutC2 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner2 4 } tempOutC3 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner3 4 } tempOutC4 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner4 4 } tempOutC5 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner5 4 } tempOutC6 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner6 4 } tempOutC7 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner7 4 } tempOutC8 OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the air conditioner OUT" ::= { conditioner8 4 } -------------------------------------------------------- stateC1 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner1 5 } stateC2 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner2 5 } stateC3 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner3 5 } stateC4 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner4 5 } stateC5 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner5 5 } stateC6 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner6 5 } stateC7 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner7 5 } stateC8 OBJECT-TYPE SYNTAX INTEGER { auto(0), cool(1), stop(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Condition of air conditioner" ::= { conditioner8 5 } -------------------------------------------------------- autoOnC1 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner1 6 } autoOnC2 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner2 6 } autoOnC3 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner3 6 } autoOnC4 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner4 6 } autoOnC5 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner5 6 } autoOnC6 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner6 6 } autoOnC7 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner7 6 } autoOnC8 OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "Manual / Automatic control" ::= { conditioner8 6 } -------------------------------------------------------- coolTimeC1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner1 7 } coolTimeC2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec.." ::= { conditioner2 7 } coolTimeC3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner3 7 } coolTimeC4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner4 7 } coolTimeC5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner5 7 } coolTimeC6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner6 7 } coolTimeC7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner7 7 } coolTimeC8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Continuous operation of the air conditioner, in sec." ::= { conditioner8 7 } -------------------------------------------------------- END